Installation
7. Connect the MA 1000 antenna ports and the MA-860 Mobile Services ports using the
four SMA to N-type cables
supplied in the accessory kit
.
NOTE: Be sure the connectors are closed at a 45 degree angle so as not to place stress on
the cables.
MA 1200
MA 1000
MA-860
A
ntennas
N-type SMA jumpers
(included)
Figure 4-4. Connection of MA-860 and MA 1000 Service Ports
4.78. Connect the power (section ).
9. Connect the coax antenna cables to the MA-860 unit antenna ports on the MA-860 front
panel according to the following instructions:
• Use 50 Ω, N-type male to male, 1/2” or 3/8” Plenum coax cables
• Max cable length (typically): 150’
10. Fit 50 ohm terminators on all unconnected SMA, AP and antenna ports.
MA-860 Installation and Configuration Guide 33