Installation
4.5.3 Add-on to an MA 1000 with MA 1200
In this type of installation, the MA-860 and MA 1000/1200 assembly are separated by a bracket.
NOTE: It is recommended to mount the MA-860 to the wall, and the MA 10001200 assembly on
top of the MA 860 (with a bracket between them). However, if a previous MA 1000/1200
assembly exists, you may install the MA-860 on top of the existing assembly, (with a bracket
between them.)
To assemble an RHU 1000 onto MA 860
1. Assemble the supplied bracket to the top of the MA-860, where the notched side of the
bracket is towards the rear of the unit. Secure the bracket to the MA-860 unit using the four
supplied screws.
T
wo screws
T
wo screws
Figure 4-3. MA-860 and Bracket Assembly
MA-860 Installation and Configuration Guide 31