Installation
4.5 MA-860 Unit Installation and Connections
MobileAccess MA-860 is typically installed in the IDF or Telecom Closet of each floor to which
WLAN coverage is to be supported. The accessories, mounting and installation procedures vary
depending on the installation configuration.
4.5.1 Standalone Wall Mount Installation
Figure 4-1. MA-860 Standalone Installation Configuration
NOTE: It is recommended to record the location of the units and IP address according to the
MAC addresses on the sticker at the rear of the units near the Ethernet port.
Although it is not required for a stand-alone installation, it is recommended to set the supplied
cable 705102101 aside (usually used when MA-860 is installed in an add-on configuration).You
will need it if you want to upgrade your system to provide additional coverage options.
ATTENTION: Use SMA wrench for the SMA connectors, do not over tighten the
connectors.
MA-860 Installation and Configuration Guide 25