User's Manual

Installation
MA-860 Installation and Configuration Guide 30
5. Connect the MA 1000 antenna ports and the MA-860 Mobile Services ports using the
four SMA to N-type cables
supplied in the accessory kit
.
NOTE: Be sure the connectors are closed at a 45 degree angle so as not to place stress on
the cables.
6. Connect the power (section
4.7).
7. Connect the coax antenna cables to the MA-860 unit antenna ports on the MA-860 front
panel according to the following instructions:
Use 50 Ω, N-type male to male, 1/2” or 3/8” Plenum coax cables
Max cable length (typically): 150’
8. Fit 50 ohm terminators on all unconnected SMA, AP and antenna ports.
M
A
-860
MA 1000 RHU
Power
A
ntenna connections
N-type SMA
jumpers (included)