User's Manual
Table Of Contents
- Preface Material
- Product Certifications
- Company Certification
- Introduction to the MA-860 System
- Element Descriptions
- Infrastructure Preparation
- Installation
- Power-up and Provisioning the Unit
- Appendix
Appendix
MA-860 Installation and Configuration Guide 54
6. Click Finish. The Device Installer Main window reappears and the
installed unit will be listed in the window.
What next?
Define the SNMP parameters according to Configuring the SNMP Parameters, page 54.
6.1.2.4 Configuring the SNMP Parameters
Configure the SNMP Community and Trap destination addresses according to the instructions in
this section.
NOTE: The required communication parameters are pre-set for each MA 850A unit. However if
you do not succeed in connecting to the Telnet application, verify the serial communication
parameter page 55 section
6.1.3
1. Select the MA 850A unit which will be configured (may be identified
according to its MAC address value) and click the Telnet button in the
toolbar.
The Telnet dialog shows the IP address of the currently connected MA 850A unit.
Figure 6-8. Telnet IP Address window
2. Click OK and immediately press Enter to go into Setup Mode. The current
settings will be displayed, followed by the Change Setup menu.
Change Setup:
0 Server configuration
1 Channel 1 configuration
3 SNMP configuration
7 factory defaults (for manufacturer use only DO NOT
SELECT!!)
8 exit without save
9 save and exit Your choice ?
3. Enter 3 (SNMP Configuration).