User's Manual

Add-on to an MA 1000 with MA 1200
MA 850 Installation and Configuration Guide 21
7. Connect the MA 1000 antenna ports and the MA 850 Mobile Services ports using the
four SMA to N-type cables
supplied in the accessory kit
.
NOTE: Be sure the connectors are closed at a 45 degree angle so as not to place stress on the cables.
Figure 3-3. Connection of MA 850 and MA 1000 Service Ports
8. Connect the power. It is recommended to use the following power supply for local power
configuration, where p
ower can also be supplied using remote power supply configurations
:
Dedicated power supply (i.e. LPS-48-100W which feeds both modules). Refer to the
Power Supplies Manual.
9. Connect the coax antenna cables to the MA 850 unit antenna ports on the MA 850 front
panel according to the following instructions:
Use 50 Ω, N-type male to male, 1/2” or 3/8” Plenum coax cables
Max cable length (typically): 150’
10. Fit 50 ohm terminators on all unconnected SMA, AP and antenna ports.
MA 1200
MA
850
MA 1000
Antennas
N-type SMA jumpers
(included)