User's Manual

Setup and Adjustment Procedure
Configuring MA 430 Controller Network Parameters
MA 2000 Installation and Configuration Guide 58
6.
If RIUs are installed, verify that the interface between the Base Units and the RIUs is
defined as ‘RIU’ and perform the adjustment procedure described in the
RIU Products
Line Installation and Configuration Guide
.
7. If RIUs are not installed, perform the adjustment procedure described in section
0.
5.2 Configuring MA 430 Controller Network Parameters
In order to monitor the MA 430 controller and all the devices it hosts, it is required to assign a
static IP address to each MA 430 controller. This is achieved through a local connection and
configuration using a terminal emulation application such as HyperTerminal.
To configuring the MA 430 IP communication parameters
1. Connect the Laptop (or any computer) on which a terminal application (such as
HyperTerminal) is installed, to the MA 430 controller RS232 front panel connector using
cable NMS-PC-DB9.
2. Launch the terminal emulation application and set the communication settings as follows:
9600 bps, 8 data bits, no parity, 1 stop bit, no flow control. The following figure shows the
HyperTerminal Port Settings dialog.
.
Figure 5-1. Terminal Emulation Application Settings