User's Manual

MA 2000 System Elements
BTS/BDA Side Elements
MA 2000 Installation and Configuration Guide 15
2.1.2 MA Base Unit
The BU (Base Unit) is a wideband device that performs RF to optical (and vice versa) conversion
of the signal on the BTS/BDA side. The BU interfaces to the RIU (or to passive BTS/BDA
interface) and the optic fiber.
Two models of MA BUs are available:
Four-port unit – supports optic connections to four RUs
Eight-port unit – supports optic connections to eight RUs
About OPTMs:
Each 4-port unit is referred to as OPTM. An 8-port unit consists of two 4-port modules or two
OPTM, as they are referred to.
NOTE: Each 4-port module is referred to as OPTM and separately managed in the MCT and NMS
management applications.
BU capabilities:
Supports all services distributed by MobileAccess systems
Fiber connection to up to 8 RUs
Setup and monitoring through connection to the host MA 410/430 controller and MCT
software application
Dry contact alarms
Front panel indicators providing status on optical link internal circuitry and signal level
MA BU Front Panel
The front panel contains the optical connections and indicators. Each four-port element has a
dedicated set of indicators (PWR, LSR and Link 1 to Link 4 or Link 5 to Link 8).
Figure 2-6. Eight-Port MA BU Front Panel
Figure 2-7. Four-Port BU Front Panel
Four ports and corresponding indicators
Four ports and corresponding indicators