User's Manual
Setup and Adjustment Procedure
Adjustment Procedure
MA 2000 Installation and Configuration Guide 63
5.5 Adjustment Procedure
NOTE: If your system includes RIU Chassis/Lite systems, refer to the RIU Product Line Installation and
Configuration Guide for detailed instructions on commissioning, configuring and monitoring RIUs.
This procedure may be performed for systems without RIUs. Although the adjustment
procedure is optional and the system will operate without it, the procedure contributes to
optimal site coverage.
The adjustments are performed at each band, where the OPTM and relevant remotes RUs are
adjusted at the low band, and only the RUs and add-on units are adjusted for each additional
band.
To adjusts sites without RIUs
1. Referring to the DS (1000/2000) for the required composite signal input to the BU for the
number of carriers and the bands, inject the low band signal at the appropriate power
directly to the OPTM.
2. Adjust the RU as follows:
• Invoke the RU configuration dialog by double-clicking on the RU in the Topology Tree
or Display View.
• Click the Adjustment tab, and click Adjust.
3. Referring to the DS (1000/2000) for the required composite signal input to the BU for the
number of carriers and the bands, inject the high band signal at the appropriate power
directly to the OPTM.
4. Adjust the OPTM as follows:
• Invoke the OPTM configuration dialog by double-clicking on the OPTM in the Topology
Tree or Display View.