User's Manual
Setup and Adjustment Procedure
Base Units Interface Definition
MA 2000 Installation and Configuration Guide 62
5.4 Base Units Interface Definition
By default, the Base Units are factory configured to connect to a passive BTS/BDA interface type.
If an RIU is included in the installation, the BTS/BDA interface for each BU must be defined
accordingly.
NOTE: The relevant Base Units are displayed under the group of host BTSC module(s) In the Topology
Tree. Each Base Unit is displayed according to its 4-port modules, where each 4-port module is referred to
as OPTM.
To verify and modify the Base Unit interface configuration
1. To invoke the BU configuration dialog, do one of the following:
• Double-click on the first OPTM node in the tree, or
• Double-click the
empty space
in the OPTM in the Base Unit view.
Do not click on the
LEDs in the OPTM –
this will invoke the RU configuration dialog.
2.
Click the Advanced tab. In the BTS Interface Type field, verify that the correct option is
selected: RIU or Passive, according to the BTS/BDA interface.
Figure 5-5: OPTM Configuration Dialog