Site Preparation
Pay special attention while connecting the SC/APC connectors - you must hear the “click
when the connection is made.
3.3.3 RF Rules
Use coax ½”, 50ohm, male-to-male N-type, (6-7dB for 1Ghz, 11dB for 2Ghz) for
connecting to RHU and RHU ports.
Use coax RG223, 50ohm, male-to-male N-type for RF connections from the BUs to the
BTS/RBS and to the RIU.
When using the MobileAccess™ system in an environment in which other indoor
coverage systems are installed, it is recommended (where possible) that the antennas
are placed at least two meters apart
When bending coax cables, verify that the bending radius does not exceed the coax
specifications.
Use wideband antennas supporting a range of 800Mhz to 2500Mhz
Use a VSWR meter (i.e. Site Master or equivalent) for checking coax cables, including the
antennas. (<2). The VSWR must be measured prior to terminating the RHUs in the
remote communication rooms
Terminate all unused RHU and RIU ports with a 50 ohm load
3.4 Power Consumption, Connections and Power
Supplies
3.4.1 Power Safety Instructions
SAFETY WARNINGS
When installing or selecting the power supplies:
Be sure to disconnect all power sources before servicing.
Battery replacement in units - only the MA 410/430 controller has batteries. MA
410/430 Controller lithium type battery should only be replaced by MobileAccess service
personnel. Risk of exploding if battery is replaced by an incorrect type. Dispose
of used batteries according to the instructions.
Calculate the required power according to the requirements of the specific installation
and then determine the configuration of the power supplies. The required DC cables will
then be determined by the selected PS configuration.
Use only UL approved power supplies
AC and DC power supply cables – use only the power cords supplied with the units
Install external over-current protective devices for the system according to the
requirements described in section
3.4.3.
MA 1000M Installation and Configuration Guide 16