Installation Guide

Installation Litenna
Installation Guide
24 Document No. 42-93-005-23D Foxcom Wireless Proprietary Information
Fiber Installation Parts List
The following parts are needed for setting up the Litenna
TM
Base and Remote Hub
Units. A fiber contractor handles cable splicing in order to connect the units. The
fiber contractor needs to use the parts list from Table 3 to arrange all equipment
necessary for setting up and installing the Litenna
TM
.
Table 3 - Fiber Installation Parts List
The following tables refer to a 46 floor building.
Equipment
Description
Quantity
Comment
Coax cable
(per 1m)
Connect RHU to antenna. As needed
Antenna As planned
Optical cable
2 x 50(fibers)
Optic cable for short
distance & protected
environments (tight buffer
type).
Total=500m
Patch panel cabinet with
SC/APC connector.
Connect jumpers to base
and pigtails to splice tray.
2
Splice box Connects optic cable from
Cabinet and pigtails to
RHU.
15 1 per 3 floors.
Splice tray Tray-1*50 connects cable
optic and pigtails near base
unit.
2
5m optical jumpers with
SC/APC connector.
Connect patch panel to
base unit.
92
5m Pigtail with SC/APC
connectors (B)
Connect patch panel and
splice tray.
92
15mPigtail
with SC/APC connectors(R)
Connects RHU and splice
box.
92
Electricity cables (per 1m) Delivers power to units. According to
length.
Electricity ducts (per 1m) Ducts for moving cables
though building.
According to
the length.
If needed
Coax connectors n-type Cable connectors as needed