Appendix A: System Specifications
MobileAccessHX Installation and Configuration Guide 32
Optical Specifications
Optical Output Power <3.0mW
Max. Optical Budget
2 dB for fiber + 1 dB for connectors (assumed) = 3 dB total. 300 m Multi-
mode
Optical Loss per Mated-pair Connectors 0.5dB (max)
Optical Connector SC/APC
Fiber Type
Single-mode: 9/125um
Multi-mode: 50/125 um or 62.5/125um (Minimum qualifications with
ANSI/TIA/EIA-568-B series, EN50173-1 or ISO/IEC 11801)
Wavelength 1310±10nm
Maximum Distance Between Base Unit and
Remote Cabinet
2km for SMF
300m for MMF
Physical Specifications – MobileAccessHX Remote Unit
Indoor Remote Unit Outdoor Remote Unit
Ports
(1) SC/APC fiber-optic pair connector
(1) N-Type female 50Ω connector for
antenna
(1) Power connector for 110/220VAC
power feed or (4) Power connectors for up
to (4) direct 48VDC power feeds
(1) D-Type 9 pins RS-232 connector for
local craft
(1) SC/APC fiber-optic pair connector
(1) N-Type female 50Ω connector for antenna
(1) Power connector for 110/220VAC power feed
or (4) Power connectors for up to 4 direct
48VDC power feeds
(1) D-Type 9 pins RS-232 connector for local
craft
Power
Local Power (AC) or Remote DC power
feed options: 90-264 V AC or 36-75V DC
Max Power Consumption: 350W
Local Power (AC) or Remote DC Power feed
options: 90-264 V AC or 36-75V DC
Max Power Consumption: 350W
Physical Dimensions
Mounting: Wall or Rack
Dimensions: 43cm x 38cm x 35cm (16.9” x
14.9” x 13.8”) [X,Y,Z]
Weight (4 Services configuration): 32Kg
(71 lb)
Mounting: Wall or Poll
Dimensions: 43cm x 63cm x 30cm (16.9” x 24.8”
x 11.8”) [X,Y,Z]
Weight (4 Services configuration): 52Kg (114 lb)
Environmental Specifications
Indoor Remote Unit Outdoor Remote Unit
Operating Temperature
0°C to +50°C (32°F to 122°F) -10°C to +50°C (14°F to 122°F)
Storage Temperature
-20°C to 85°C (-4°F to 185°F) -20°C to 85°C (-4°F to 185°F)
Humidity 10% to 95%, non-condensing -
Ingress Protection - IP65