User's Manual

Provisioning the MobileAccessHX Basic Setup Procedure
MobileAccessHX Installation and Configuration Guide 29
Low 1 -30 13 Set in cases where mobile stations are
very near to the HX antenna (e.g. in
cases where HX unit antenna port is
splitted to multiple lower power antennas
to cover standard office building)
Normal 11 -40 10 Default for standard HX installations
High 21 -50 7 Set in cases where mobile stations are
located far from the HX antenna (e.g. in
a parking lot, where the HX unit is
mounted high on a pole).
* Max. NF = Typical NF + 4dB
7. In the DL Adjustment tab, perform DL adjustment manually to complete the commissioning
procedure.
Set the Target Max Pwr (Target Pout) value according to site planning requirements.
Default Target Max Power value is the maximum value per each band (e.g. 33 dBm for
700LTE band).
DL Output Power can be adjusted to a lower level (up to 10dB lower) as required.
Click the Adjust button.
Confirm that the adjustment procedure is successful (Adjust Result shows “Success”)
and verify actual readings of Adj. Date and DL Output Pwr .
If adjustment procedure fails, refer to the RF Parameters tab, click the Restore
button and perform adjustment again.
THE HX SETUP PROCEDURE IS NOW COMPLETE
Click to select
Target Max Power
Click to perform RF adjustment
according to Target Max Power
Verify successful results
Adjustment Date and Actual
DL Pwr reading