User's Manual
Table Of Contents
- Reporting Defects
- NOTE: Keep all packing material until you have completed the inspection
- Compliance with RF safety requirements:
- MobileAccess products have no inherent significant RF radiation.
- Compliance with RF safety requirements:
- ISO ISO 9001: 2000 and ISO 13485: 2003
- About this Guide and Other Relevant Documentation
- Table of Contents
- Introduction to HX System
- System Installation
- Rack Brackets (supplied screws)
- Commissioning MA Head-End
- Provisioning the MobileAccessHX
- Appendix A: System Specifications
- Appendix B: Ordering Information
- Appendix C: Site Preparation
Provisioning the MobileAccessHX Accessing HX Management Options
MobileAccessHX Installation and Configuration Guide 24
4
4
P
P
r
r
o
o
v
v
i
i
s
s
i
i
o
o
n
n
i
i
n
n
g
g
t
t
h
h
e
e
M
M
o
o
b
b
i
i
l
l
e
e
A
A
c
c
c
c
e
e
s
s
s
s
H
H
X
X
Once the required physical connections have been completed, the HX unit is automatically
detected (auto-discover) by the SC-450 and can be remotely monitored and managed.
The MobileAccessHX Remote Unit is centrally managed via the MobileAccess SC-450 Controller.
Note that MobileAccessHX is not connected directly to the controller. It is connected to the Base
Unit (that is connected to the controller). Thus, the controller monitors views and manages the
HX via the Base Unit to which the HX is connected.
Note: The provisioning procedure consists of two simple steps: assign the unit name (Module
Info tab) and click the Adjust button (Adjustment tab). Additional configuration options are
available as well.
Each HX unit can be managed via several dedicated panes that are accessed by clicking the
relevant HX item in the SC-450 Topology Tree.
4.1 Accessing HX Management Options
To access the MobileAccessHX management options
In the Network Topology tree, expand the relevant Controller item, expand the relevant
Base Unit (to which the HX is connected) and click on the HX. The HX alarms and management
tabs appear.
The HX Cabinet Alarms are continuously displayed (to the left of the tabs). The monitoring
and configuration options are distributed over four tabs:
• Module Info - device version and identification definitions
• RF Parameters – service control options.
HX item
Host Base Unit
HX Alarm
status
Four management
tabs
Controller