User's Manual

Commissioning MA Head-End RIU Configuration
MobileAccessHX Installation and Configuration Guide 21
6. The DL power gain may be set automatically (AGC) or manually (DCA Digital Control
Attenuation). To control the DL gain control, set the DL AGC Status:
ON Enables automatic gain control to compensate for input power variations. When
enabled, gain control is performed automatically.
OFF – Disables automatic gain control and enables DCA to be set manually (DL DCA
Manual Override Value).
7. UL Atten. Value Controls attenuation on the uplink. This value is set during
manufacturing and should be modified only under special circumstances.
8. Sup. Parameters tabRelevant only for the initial adjustment procedure of the complete
system (See LTE addendum document:
UMA_MA1000 MA2000_700MHz LTE AO
). Otherwise
disregard.
This option provides an internal signal generation source that can be used during the
adjustment procedure instead of connecting an external signal generator.
ON Internal signal source activated.
OFF – Internal signal source disabled.