Corning Optical Communications User Manual I CMA-066-AEN I Page 56
5.3.2 Outdoor Remote Unit
Ports
(2)
Corning OptiTap® fiber optic waterproof connectors (1 for UL and 1 for DL)
(1)
N-Type female 50Ω connector for antenna
(1)
Waterproof power connector – model dependent:
• AC model: 1-20UNEF, plug, 3-pin waterproof, solder for panel, power connector for
100/240 VAC power feed
• DC model: 1-20UNEF, plug, 8-pin waterproof , solder for panel, power connector for 25-
48 VDC power feed
(1)
D-Type 9 pins RS-232 waterproof connector for local craft
(2)
SMA type Test Port connectors (one UL and one DL) – model dependant
Power
• HX Outdoor AC: 100/240 VAC; FUSE,250V/8A,6.35x32 mm, slow blow
• HX Outdoor DC: 25-48V DC; FUSE,250V/16A,6.35x32 mm, slow blow
• Max Power Consumption: 340 W
Physical
Characteristics
Mounting: Wall or Pole
Dimensions (H x W x D) (mm): 24.2’’* x17.5’’x 11.4’’ (615* x 442 x 285.3)
*without ‘Brush Ring’
Weight (four services configuration): 88 lbs (40 kg)
Cooling Feature
Passive heat dissipation (Heat Sink)
5.4 Environmental Specifications
Indoor Remote Unit
Outdoor Remote Unit
Operating
Temperature
0°C to +50°C (32°F to 122°F) -30°C to +65°C (-22°F to 149°F)
Storage Temperature
-20° to 85°C (-4° to 185°F) -20° to 85°C (-4° to 185°F)
Humidity
10% to 90%, non-condensing 10% to 90%, non-condensing
Enclosure
-
NEBS OSP Class 4 rated (Enclosure protected from
elements and waterproofing)
5.5 Standards and Certifications
Laser Safety
• CDRH 21 CFR 1040.10, 1040.11 (Except for deviations per notice No.50, July 26, 2001)
• IEC 60825-1, Amendment 2 (January 2001)
• EN 60825-1
CE
Radio Equipment and Systems:
• EN 301 502 – for GSM / EGSM Frequency Bands
• EN 300 609 – for DCS Frequency Band
• EN 301 893 – for WLAN 802.11a EN 301 908 – for UMTS Frequency Band
EMC: EN 301 489
FCC
Radio Equipment and Systems:
• FCC 47 CFR Part 22 – for CELL Frequency Band
• FCC 47 CFR Part 24 – for PCS Frequency Band
• FCC 47 CFR Part 27 – for 700 LTE and AWS Frequency Bands
EMC: FCC 47 CFR Part 15 Subpart B
Safety
• EN 60950; UL 60950