User's Manual

Table Of Contents
Corning Optical Communications User Manual I CMA-066-AEN I Page 56
5.3.2 Outdoor Remote Unit
Ports
(2)
Corning OptiTap® fiber optic waterproof connectors (1 for UL and 1 for DL)
(1)
N-Type female 50 connector for antenna
(1)
Waterproof power connector model dependent:
AC model: 1-20UNEF, plug, 3-pin waterproof, solder for panel, power connector for
100/240 VAC power feed
DC model: 1-20UNEF, plug, 8-pin waterproof , solder for panel, power connector for 25-
48 VDC power feed
(1)
D-Type 9 pins RS-232 waterproof connector for local craft
(2)
SMA type Test Port connectors (one UL and one DL) model dependant
Power
HX Outdoor AC: 100/240 VAC; FUSE,250V/8A,6.35x32 mm, slow blow
HX Outdoor DC: 25-48V DC; FUSE,250V/16A,6.35x32 mm, slow blow
Max Power Consumption: 340 W
Physical
Characteristics
Mounting: Wall or Pole
Dimensions (H x W x D) (mm): 24.2’’* x17.5’’x 11.4’’ (615* x 442 x 285.3)
*without ‘Brush Ring’
Weight (four services configuration): 88 lbs (40 kg)
Cooling Feature
Passive heat dissipation (Heat Sink)
5.4 Environmental Specifications
Indoor Remote Unit
Outdoor Remote Unit
Operating
Temperature
0°C to +50°C (32°F to 122°F) -30°C to +65°C (-22°F to 149°F)
Storage Temperature
-20° to 85°C (-4° to 185°F) -20° to 85°C (-4° to 185°F)
Humidity
10% to 90%, non-condensing 10% to 90%, non-condensing
Enclosure
-
NEBS OSP Class 4 rated (Enclosure protected from
elements and waterproofing)
5.5 Standards and Certifications
Laser Safety
CDRH 21 CFR 1040.10, 1040.11 (Except for deviations per notice No.50, July 26, 2001)
IEC 60825-1, Amendment 2 (January 2001)
EN 60825-1
CE
Radio Equipment and Systems:
EN 301 502 for GSM / EGSM Frequency Bands
EN 300 609 for DCS Frequency Band
EN 301 893 for WLAN 802.11a EN 301 908 for UMTS Frequency Band
EMC: EN 301 489
FCC
Radio Equipment and Systems:
FCC 47 CFR Part 22 for CELL Frequency Band
FCC 47 CFR Part 24 for PCS Frequency Band
FCC 47 CFR Part 27 for 700 LTE and AWS Frequency Bands
EMC: FCC 47 CFR Part 15 Subpart B
Safety
EN 60950; UL 60950