User's Manual

Table Of Contents
Corning Optical Communications User Manual I CMA-066-AEN I Page 55
5.2 Optical Specifications
Optical Output Power
<3.0 mW
Max. Optical Budget
2 dB for fiber + 1 dB for connectors (assumed) = 3 dB total. 300 m Multi-mode
Optical Loss per Mated-pair
Connectors
0.5 dB (max)
Optical Connector
Indoor: SC/APC
Outdoor: Corning OptiTap®
Fiber Type
Single-mode: 9/125µm
Multi-mode: 50/125 µm or 62.5/125µm (Minimum qualifications with ANSI/TIA/EIA-
568-B series, EN50173-1 or ISO/IEC 11801)
Wavelength
1310 ± 10 nm
Maximum Distance Between Base
Unit and Remote Cabinet
2 km for SMF
5.3 Physical Specifications
5.3.1 Indoor Remote Unit
Ports
One SC/APC fiber-optic pair connector or two for MIMO models
One N-Type female 50Ω connector for antenna (two connectors for MIMO models)
One Power connector (model dependent):
AC models: One power connector for 90-264VAC power feed
DC models: One 18 pin power connector for 25-48VDC power feeds
One D-Type 9 pins RS-232 connector (or two for MIMO models) for local craft
Two SMA type Test Port connectors (one UL and one DL) model dependant
Power
HX Indoor AC: 90-264 VAC; FUSE,250V/8A,5x20mm, slow blow fuse
HX Indoor DC: 25-48V DC; 18 pin connector supports 20-
30 AWG wires; Max. current
(per pin) = 5A
Max Power Consumption: 350 W (SISO models), 500 W (MIMO models)
Fuses: Includes two internal fuses
Physical Characteristics Mounting: Wall or Rack
Dimensions (H x W x D): 13.8 x 16.9 x 14.9 in (350 x 429 x 378 mm)
Weight: Three Services SISO configuration: 66 lbs (30 kg)
Four Services SISO configuration: 71 lbs (32 kg)
Two SISO and two MIMO services configuration: 92 lbs (42 kg)
Cooling Feature
Active heat dissipation (Fan)