4 HX Outdoor Physical Installation
4.1 General Information
The HX Outdoor Remote Unit can be installed either on a wall or on a pole (brackets are provided to facilitate both
options).
The unit weighs 40 kg (88.2 lbs). This requires two people or the use of a crane (from top ring) to lift the unit onto the
pole.
The wall mount and pole mounting procedures described in this document are recommendations for the specified
scenarios. The installer should do the homework to use the proper hardware and industry standard mounting procedure
required for installing 88lbs unit on the varying types of wall & pole scenarios that could exist in the field.
The wall mounting and pole mounting scenarios are modeled and simulated for hurricane and zone-4 earth quake
impact per GR-487 standard.
All outdoor or weather/water exposed installations need to use stainless steel or hot-dipped galvanized anchors.
The HX Outdoor unit must be mounted with the connectors facing down.
The power connections are model dependent refer to the wiring guide (supplied with each unit) for the connections to
the HX power connector.
Ensure that the HX is properly grounded (refer to the grounding feature on the bottom port panel of the HX).
4.2 Unpacking and Inspection
Unpack and inspect the packages as follows:
1. Open the shipping carton and carefully unpack each unit from the protective packing material.
2. Verify that all the items have been received.
3. Check for signs of external damage. If there is any damage, call your Corning Optical Communications service
representative.
Description
Quantity
Image
P/N
HX Outdoor Remote Unit Cabinet 1
HX-C85P19L70A17-AC-B (or)
HX-C85P19L70A17-DC-B (or)
HX-C85G91D18U21-AC-B (or)
HX-C85G91D18U21-DC-B (or)
HX-G90D18U21-AC-B (or)
HX-G90D18U21-DC-B
Four Hole Bracket Template for
marking required holes for drilling
1
Flat Washer, 3/8" 8
631F000801
Nut,3/8, DIN 934 -3/8 UNC 8 631N001001
Spring Washer, 3/8" 8 631P000501
Hex Cap Screw, 3/8 x6", Head 9/16 8 631S002901
Power cable with open edges
Length=10 M.
1
HX Outdoor AC - 705A030451 (AC cable)
HX Outdoor DC - 705A030851 (DC Cable)
Conn. 1-20UNEF,Receptacle, solder
f/cable, waterproof
1
HX Outdoor AC - 616A010401 (3 Pins)
HX Outdoor DC - 616A011801 (8 Pins)