User's Manual

Table Of Contents
Corning Optical Communications User Manual I CMA-066-AEN I Page 23
2.4 Fiber Optic Requirements
2.4.1 Authorized Optic Cables
Only single mode fiber can be used with HX Indoor/Outdoor products,
All fiber in a given length of fiber must be of the same core diameter.
For HX Indoor models:
All Bulkhead adapters must be either Single SC APC (Green) adapters.
All terminations, cross connections or patches must be direct fusion splice or Corning specified patch cords listed
below.
900 microns pathcord for splicing, 2 Meters, 2xSC/APC
Diamond p/n ENC/1045341 Beige boots, 62.5/125/900 MA# 500001057
Diamond p/n ENC/1045340 Black boots, 50/125/900 MA# 500001058
Zipcord patchcord, 4xSC/APC, 50/125/900/2000/4500 micron
Diamond p/n ENC/1045342 Black/Brown boots, 1 Meter MA# 50000105
Diamond p/n ENC/1045343 Black/Brown boots, 3 Meter MA# 500001060
Zipcord patchcord, 4xSC/APC, 62.5/125/900/2000/4500 micron
Diamond p/n ENC/1045344 Beige/Brown boots, 1 Meter MA# 500001061
Diamond p/n ENC/1045345 Beige/Brown boots, 3 Meter MA# 500001062
For HX Outdoor models :
Use Corning OptiTap™ cables:
Part Number Description
434401EB4R2005M-P
OptiTap® to SC/APC 5 meters
434401EB4R2030M-P
OptiTap ®to SC/APC 30 meters
434401EB4R2100M-P
OptiTap® to SC/APC 100 meters