User Manual
Table Of Contents
- Warranties
- Hardware
- Software Warranty
- Notwithstanding the foregoing, Corning shall have no obligation under the Software Warranty if the
- Returns
- Limitations of Liabilities
- Reporting Defects
- Warnings and Admonishments
- RF Safety
- Compliance with RF safety requirements:
- Power requirements for DC Inputs
- Laser Safety
- Care of Fiber Optic Connectors
- Regulatory Compliance Information
- Standards and Certifications
- Licensee Contact Information
- About this Guide
- Additional Relevant Documents
- List of Acronyms
- Table of Contents
- 1.1 Key Features and Capabilities
- 1.2 System Architecture
- 1.3 System Monitoring and Management
- 1.4 HX Unit Description
- 1.5 External Passive Module (EPM)
- 1.6 Site Considerations
- 1.7 Environmental
- 1.8 Installation Requirements
- 1.9 Fiber Optic Requirements
- 1.10 RF Coaxial Cable Guidelines
- 1.11 Antenna Specifications and Guidelines
- 1.12 Grounding Requirement
- 1.13 Manual Handling
- 1.14 Installation Requirements
- 1.15 Unpacking and Inspection
- 1.16 Mounting
- 1.17 Connections
- 1.18 Verifying Normal Operation
- Appendix A: System Specifications
- RF Parameters
- Supported Services
- RF Parameters per Service Antenna Port
- RF Parameters for Diplexer External Input Port
- Physical Specifications
- Standards and Approvals
- Appendix B: Ordering Information
- MobileAccessHX WCS Remote Units
Appendix A: System Specifications
CMA-318-AEN
Page 53
Physical Specifications
Interfaces
Chassis:
• One Min DIN 4.3-10 duplexed antenna (‘ANT’) port per multiplexer (one for SISO
units; two for MIMO units)
• One Min DIN 4.3-10 duplexed ‘Expansion’ port per multiplexer (one for SISO
units; two for MIMO units) for interfacing external RF In source
• One SMA-Type female 50Ω port for DL test port per multiplexer (one for SISO
units; two for MIMO units)
• One female RJ-45 local craft port
• One D-Type 9 pin female console port (engineering GUI)
• One six pin pluggable terminal block connector; three VCC and GND pairs
• One two hole grounding lug with 6 gauge wire
• One DB-9 female external alarm connector for external dry contact alarm
connections
Module:
• Four SC APC optical connectors
• Two SMA UL/DL Extension Port connectors
Power
• Power Input: 34-48 V DC
• Maximum operating voltage : 28-60 V DC
• Max Power Consumption: 90 W (SISO models); 150 W (MIMO models)
•
Physical Mounting: Wall or 19-in Rack
Dimensions (H
x W x
D):
7.0 x 19 x 15.4 in (176.5 x 492 x 392 mm)
Weight:
SISO Services configuration: 48lbs (21.77kg) for SISO-
PLUS / 43lbs (19.5
kg) for SISO-NU
MIMO Services configuration: 55 lbs (24.95 kg)
Cooling Feature Active heat dissipation (Fan)
Environmental Specifications
Operating Temperature
-40°C to +65°C (-40°F to 149°F)
Storage Temperature
-40°C to +85°C (-40°F to 185°F)
Humidity
10% to 95%, non-condensing
Enclosure