4. Open cabinet door to access HX WCS module(s) with the fiber optic interface, route the DL and UL fibers
through the front door slot and (see Figure 3-17) and connect as follows:
Optic fiber connections to/from headend (BU):
o Downlink: Connect the fiber optic cable pigtails from splice box, leading from the BU port, to the
corresponding HX WCS module “From HE” SC APC optic port (MIMO models include two service
modules with fiber connections).
o Uplink: Connect the fiber optic cable pigtails from splice box, which comes from the HX WCS service
module(s), “From HE” SC APC uplink port to the BU.
Using fiber optic jumpers, connect the HX WCS module “To RU” SC APC optic to the SC APC optic port of
the MA1000/MA2000 remote unit.
IMPORTANT! Keep in mind the rules for handling and connecting F/O cables.
Example of HX WCS Fiber optic Connections to BU and MA2000 Remote Indoor Connections
(MIMO)
Figure 3-25