User Manual
Table Of Contents
- Warranties
- Hardware
- Software Warranty
- Notwithstanding the foregoing, Corning shall have no obligation under the Software Warranty if the
- Returns
- Limitations of Liabilities
- Reporting Defects
- Warnings and Admonishments
- RF Safety
- Compliance with RF safety requirements:
- Power requirements for DC Inputs
- Laser Safety
- Care of Fiber Optic Connectors
- Regulatory Compliance Information
- Standards and Certifications
- Licensee Contact Information
- About this Guide
- Additional Relevant Documents
- List of Acronyms
- Table of Contents
- 1.1 Key Features and Capabilities
- 1.2 System Architecture
- 1.3 System Monitoring and Management
- 1.4 HX Unit Description
- 1.5 External Passive Module (EPM)
- 1.6 Site Considerations
- 1.7 Environmental
- 1.8 Installation Requirements
- 1.9 Fiber Optic Requirements
- 1.10 RF Coaxial Cable Guidelines
- 1.11 Antenna Specifications and Guidelines
- 1.12 Grounding Requirement
- 1.13 Manual Handling
- 1.14 Installation Requirements
- 1.15 Unpacking and Inspection
- 1.16 Mounting
- 1.17 Connections
- 1.18 Verifying Normal Operation
- Appendix A: System Specifications
- RF Parameters
- Supported Services
- RF Parameters per Service Antenna Port
- RF Parameters for Diplexer External Input Port
- Physical Specifications
- Standards and Approvals
- Appendix B: Ordering Information
- MobileAccessHX WCS Remote Units
오류! 지정한 스타일은 사용되지 않습니다.
CMA-TBD-AEN
Page 25
1.9 Fiber Optic Requirements
1.9.1 Authorized Optic Cables
• Only single mode fiber can be used with HX WCS product
• All fiber in a given length of fiber must be of the same core diameter.
• All bulkhead adapters must be single mode SC APC (Green) adapters.
• All terminations, cross connections or patches must be direct fusion splice or Corning specified patch cords
listed below.
900 microns pathcord for splicing, 2 Meters, 2xSC/APC
Diamond p/n ENC/1045341 Beige boots, 62.5/125/900 MA# 500001057
Diamond p/n ENC/1045340 Black boots, 50/125/900 MA# 500001058
Zipcord patchcord, 4xSC/APC, 50/125/900/2000/4500 micron
Diamond p/n ENC/1045342 Black/Brown boots, 1 Meter MA# 50000105
Diamond p/n ENC/1045343 Black/Brown boots, 3 Meter MA# 500001060
Zipcord patchcord, 4xSC/APC, 62.5/125/900/2000/4500 micron
Diamond p/n ENC/1045344 Beige/Brown boots, 1 Meter MA# 500001061
Diamond p/n ENC/1045345 Beige/Brown boots, 3 Meter MA# 500001062
1.9.2 Fiber Optic Rules
ATTENTION!
Please also refer to the laser safety section in the document preface.
• Fiber optic cables require proper handling. Do not stretch, puncture, or crush the fiber cable(s) with staples,
heavy equipment, doors, etc.
• Always maintain the minimum bending radius specified by the cable manufacturer. The minimum bend radius
is usually 10 times the cable's outer diameter. In the case of single optical fiber that is not in a cable, the
minimum bending radius to be observed is 30 mm.
• Use SC APC connectors (green color) 8 deg only.
• Pay special attention while connecting the SC APC connectors - ensure that you hear a “click”, indicating a
secure connection
• Use minimum splicing/connectors to achieve minimum losses on the fibers.
• Use precaution while installing, bending, or connecting fiber optic cables.
• Use an optical power meter and OTDR for checking the fiber optic cables.
• Make sure the environment is clean while connecting/splicing fiber optic cables.
• All fiber optic connectors should be cleaned prior to connecting to the system
• Fiber connector protective caps should be installed on all non-terminated fibers and removed just before they
are terminated.
• Check the fiber optic connections.