- 1 Introduction
- 2 Installation Guidelines
- 3 Physical Installation
- Appendix A: System Specifications
- RF Parameters
- Supported Services
- RF Parameters per Service Antenna Port
- RF Adjustment
- OverPower Protection Mechanism
- Power Down Mechanism
- RF Parameters for External Wideband and WCS Input Ports
- Physical Specifications
- Standards and Approvals
- Appendix B: Ordering Information
Corning Restricted - Draft for public release
Appendix A: System Specifications
CMA-XXX-AEN
Page 56
Physical Specifications
Interfaces
Chassis:
• One mini DIN 4.3-10 Type duplexed antenna (‘ANT’) port per multiplexer
• One mini DIN 4.3-10 Type duplexed (‘WCS RU’) port per multiplexer (one for SISO
and two for MIMO configurations) for interfacing to HX WCS RF input
• One N-Type duplexed wideband (“WB RU”) port per multiplexer for interfacing to
HX4 remote unit
• One SMA-Type female 50Ω port for DL test port per multiplexer (one for SISO and
two for MIMO configurations)
• One female RJ45 Ethernet port for local craft
• One DB-9 pin female RS232 console port (engineering GUI)
• One DB-9 female external alarm connector for external dry contact alarm
connections
• Two DB-9 female RS232 console ports (engineering GUI) for connected external RF
modules
• One SMA type connector for TDD sync monitoring
• One two-hole grounding lug compatible with 6 AWG wire
• One 8-pin pluggable terminal block DC connector; three VCC and GND pairs
Module:
• One SC APC optical connector
• Two SMA UL/DL Extension Port connectors (future option)
Power
• Power Input: 34-48 V DC
• Maximum operating voltage : 28-60 V DC
• Max Power Consumption: 90 W (3A)(SISO models); 150 W(5A) (MIMO models)
Physical Mounting: Wall or 19-in Rack
Dimensions (H x W x D): 7.0 x 19 x 15.4 in (176.5 x 492 x 392 mm)
Weight:
SISO Services configuration: 48 lbs (21.77 kg)
MIMO Services configuration: 55.11 lbs (25 kg)
Cooling Feature Active heat dissipation (Fan)
Environmental Specifications
Operating Temperature -20° to +60°C (-4° to 140°F)
Storage Temperature -40° to 85°C (-40 to 185°F)
Humidity
10% to 95%, non-condensing
Ingress protection IP20; with outdoor enclosure: GR487