User's Manual
Table Of Contents
- Warranties
- Hardware
- Software Warranty
- Returns
- Limitations of Liabilities
- Reporting Defects
- Warnings and Admonishments
- RF Safety
- Compliance with RF safety requirements:
- Power requirements for DC Inputs
- Laser Safety
- Care of Fiber Optic Connectors
- Regulatory Compliance Information
- Standards and Certifications
- Licensee Contact Information
- About this Guide
- Additional Relevant Documents
- List of Acronyms
- Table of Contents
- 1 Introduction
- 2 Installation Guidelines
- 3 Physical Installation
- Appendix A: System Specifications
- RF Parameters
- Supported Services
- RF Parameters per Service Antenna Port
- RF Adjustment
- OverPower Protection Mechanism
- Power Down Mechanism
- RF Parameters for External Wideband and WCS Input Ports
- Physical Specifications
- Standards and Approvals
- Appendix B: Ordering Information
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 48
3.3.2 Fiber Connections
HX 2.5 GHz TDD support single mode fiber connections and interfaces to the OCH-WDM located at the headend via
the fiber patch panel.
Note: HX 2.5 GHz TDD supports connections to OCH-WDM, whereas the HX4 and HX WCS support connections to
BUs.
To perform fiber connections
Open cabinet door to access HX 2.5 GHz TDD module(s) with the fiber optic interface, route the DL and UL fibers
through the front door slot and (see Figure
3-20) and connect the fiber optic cable pigtails from splice box, leading from
the OCH port, to the corresponding HX 2.5 GHz TDD module SC APC “Optic Port” (MIMO models include two service
modules with fiber connections).
IMPORTANT! Keep in mind the rules for handling and connecting F/O cables.
Example of HX 2.5 GHz TDD Fiber Connections to OCH (MIMO)
Figure 3-20