User's Manual

Table Of Contents
Corning Restricted - Draft for public release
Physical Installation
CMA-XXX-AEN
Page 31
3.2.3 Wall-Mount Installation
IMPORTANT! The wall-mount installation procedures in this section are for concrete/brick walls. For other wall types,
installer is responsible for following standard practices using the appropriate tools and materials.
The following sections provide instructions for both vertical (“belly-to-wall”) and horizontal (optional “back-to wall”) wall-
mount installation types.
Note the following:
If the HX 2.5 GHz TDD is to be installed in conjunction with the EPM, the latter must be assembled to the HX 2.5
GHz TDD unit before mounting on the wall. Refer to 3.2.3.1.
When selecting the installation location, make sure that there is enough clearance distance from the bottom to
open the HX 2.5 GHz TDD chassis door.
3.2.3.1 Assembling EPM to HX 2.5 GHz TDD (for Configurations with EPM)
Additional required items (not provided)
Six UNC 6-32, 11 mm screws for assembling EPM onto HX 2.5 GHz TDD unit.
To assemble EPM onto HX 2.5 GHz TDD
1. Remove the factory assembled rack ears from the sides of the unit.
2. Six fixed holes on top of the EPM are used for mounting the unit onto the HX 2.5 GHz TDD. See Figure
3-4.
Fixed Holes on EPM for Mounting on HX 2.5 GHz TDD
Figure 3-3