User's Manual
Table Of Contents
- Warranties
- Hardware
- Software Warranty
- Returns
- Limitations of Liabilities
- Reporting Defects
- Warnings and Admonishments
- RF Safety
- Compliance with RF safety requirements:
- Power requirements for DC Inputs
- Laser Safety
- Care of Fiber Optic Connectors
- Regulatory Compliance Information
- Standards and Certifications
- Licensee Contact Information
- About this Guide
- Additional Relevant Documents
- List of Acronyms
- Table of Contents
- 1 Introduction
- 2 Installation Guidelines
- 3 Physical Installation
- Appendix A: System Specifications
- RF Parameters
- Supported Services
- RF Parameters per Service Antenna Port
- RF Adjustment
- OverPower Protection Mechanism
- Power Down Mechanism
- RF Parameters for External Wideband and WCS Input Ports
- Physical Specifications
- Standards and Approvals
- Appendix B: Ordering Information
Corning Restricted - Draft for public release
Introduction
CMA-xxx-AEN
Page 17
1.4.1 HX 2.5 GHz TDD External Interfaces
The HX 2.5 GHz TDD front panel includes the multiplexer interfaces (e.g. antenna port, DL Test port, wideband RU
port), system level status LEDs and service maintenance ports.
Note: Both SISO and MIMO models include two sets of multiplexer RF interfaces. For SISO models, the RF
connections will be performed via the connectors corresponding to the installed HX remote unit module (inside chassis):
Left MUX for Left HX 2.5 GHz Module and Right MUX for Right HX 2.5 GHz Module. See section
1.4.2 for internal
modules.
HX 2.5 GHz TDD Front Panel Interfaces
Figure 1-6
Table 1-1 provides a description of the front panel connectors.
Connector
Description
ANT.
Mini DIN 4.3-10 type duplexed antenna port (one per multiplexer)
CPL.
SMA-Type female 50Ω coupling port (-40 dB ± 1.0 dB) used for RF DL test (one per
multiplexer)
WB RU
N-Type duplexed wideband remote unit expansion port for interfacing to HX4
remote (one per multiplexer) so that additional HX4 services are combined with
those of the HX 2.5 GHz TDD and distributed from its antenna port
WCS RU
Mini DIN 4.3-10 Type duplexed port (one per multiplexer) for interfacing to HX WCS
RF input so that additional WCS service is combined with those of the HX 2.5 GHz
TDD and distributed from its antenna port
Ext. 1 / Ext. 2
N/A (Future option)
GND
Two-hole, standard barrel grounding lug
Ext. Alarms
DB-9 female external alarm connector for external dry contact alarm connections;
Supports up to four external alarms (configurable via the Web GUI)
RS-232
D-Type 9 pin female console port used for connecting to engineering GUI
T-Sync
SMA type connector for TDD sync monitoring
Ethernet
Ethernet connection for local craft
Table 1-1. HX 2.5 GHz TDD Front Panel Connectors