3.3.2 Mounting the External Combiner
3.3.2.1 Wall mount
1. Using the combiner bracket mounting holes as a guide mark and drill four holes for the provided M6 bolts
2. Mount combiner on wall using the M6 bolts, spring and flat washers (four of each) provided in the External Combiner Kit.
3.3.2.2 Pole mount
Slip a hose clamp through each end of the factory assembled mounting bracket (see Figure 3-24) and secure to pole by
tightening.
Figure 3-24. Hose Clamp Installation Holes
Figure 3-25. Example of Combiner with Hose