3.2 Installing the GX unit
3.2.1 Selecting Mounting Location
Select the mounting location (wall/pole):
General surroundings
Ventilated and easy-to-reach area
Proximity to the antenna in order to minimize cable loss
For installations with GX external multiplexer - take into consideration that the unit must be mounted adjacent to the GX RF
interfaces to facilitate the connections (DIN-DIN cables = 1.2 m).
3.2.2 Unpacking and Inspection
Unpack and inspect the cartons according to the following procedure
1. Open the shipping carton and carefully unpack each unit from the protective packing material.
2. Please verify that the items listed in Table 3-2 are included in your package (image size is not proportional) and check for
signs of external damage. If there is any damage, call your Corning service representative.
Item
Quantity
Image
GX Quad-band Remote Unit
1
Mounting bracket (used for both pole and wall installations)
1
M8 Nuts, spring washers Φ8, plain washers Φ8 (used for securing
Remote Unit when hanged on bracket protrusions)
2
(per item)
Masonry bolt (set) M10x110 – used for wall mount installations
6
Power Supply Cable (AC) – for AC models
1