- 1 Introduction to GX System
- 2 System Installation
- 3 Commissioning MA Head-End
- 4 Provisioning the MobileAccessGX
- Appendix A: System Specifications
- Appendix B: Ordering Information
- Appendix C: Site Preparation
MobileAccessGX Installation and Configuration Guide 14
Figure 2-5. Hanging GX Slots on Bracket Nuts
Figure 2-6. GX Mounted on Wall
2.6.3.2 Pole Mount Installation
NOTE: For pole mount, Hose Clamps are provided but it is recommended to acquire
two U-bolts, corresponding to your pole diameter that fit through the holes in the provided
brackets.
To mount the unit on a pole
1. Select the appropriate location according to the following criteria:
Accessibility
Antenna location and distance
2. Secure the mounting brackets to the pole using one of the following options:
a. U-Bolt (not supplied): Insert one U-Bolt (per bracket) through the two mounting holes
of each bracket and secure the brackets to the pole at the indicated
distance of 123.9cm
.
See Figure 2-7.
Hang on brackets’
protruding bolts
Hang on brackets’ protruding
screws
PULL DOWN
FIRMLY