Coupling Specifications
Frequency (MHz) Typical Coupling* (dB)
WCS -50.0
2.5 GHz TDD -50.0
*
Depending on the band, the actual coupling value may slightly vary.
Optical Specifications
Parameter Value
Maximum Optical Budget 6 dBo
Optical Return Loss > 50 dB
Optical Loss per Mated-pair
Connectors
0.5 dB (maximum)
Optical Connector OptiTap
®
fiber optic waterproof connector
Optical Automatic Gain Control
Range
-2 to -10 dBm
Fiber Type Single-mode: 9/125 μm
Wavelength 1310 nm, 1550 nm + WDM
Physical Specifications
Parameter Value
Ports OptiTap fiber optic waterproof connector; One for SISO and two for MIMO
RF DIN duplexed female connectors; One for SISO and two for MIMO
Two 1/4-in grounding screws for AWG #18 GND cable
One RJ45 waterproof LAN connector
Power Dual-Band
SISO
Dual-Band
MIMO
AC: Input: VAC 100 - 240/47-63 Hz
Maximum power consumption: 750 W 1100 W
DC: Input: VDC (-40) to (-57)
Maximum power
consumption:
750 W 1100 W
Physical Characteristics Weight: 147 lb (66.6 kg)
Mounting: Wall-mountable or pole-mountable
Dimensions: 53.15 x 8.9 x 12.4 in (1350 x 226.06 x 314.96 mm)
Cooling Feature Active heat dissipation (fan)