User's Manual

Corning Optical Communications User Manual
|
CMA-601-AEN
|
Page 25
Figure 3.8 provides an overview of the mounted GX unit.
Overview of Mounting Procedure | Figure 3.8
7. Position the GX and bracket assembly so that the
mounting brackets face the wall. Refer to “side view”
(top left image) and “front view” (top right image) shown
in Figure 3.8.
8. Using the screw holes as a template, drill the required
holes in the floor and wall (drill directly through the screw
holes). Refer to “Front View” (top-right image) and “Top
View” (bottom-left image) shown in Figure 3.8.
Note: Eight M10 masonry bolts are required (not provided).
9. Insert masonry M10 bolts into drilled holes and tighten.
Refer to Figure 3.9.
Location of Inserted Masonry Bolts | Figure 3.9
3.6.2 Wooden Pole-Mountable Installation
This section provides instructions on how to mount the GX
quad-band unit on wooden poles using the GX wooden-pole
bracket accessory kit (ordered separately).
Note the following:
This bracket is designed for installations on wooden poles
only.
Up to two GX units can be mounted on a single bracket, one
on each side.
Two people are required for mounting each GX unit onto
the bracket.