User's Manual

Commissioning the System
P/N 709C011801
Page 76
6.6.2 Default Values Assigned in Setup Tool
Each phase of the Setup Tool consists of configuring various parameters or settings, where default values are provided, enabling
the user to continue to the next phase can if no other user input is given. Refer to the following table for the default values.
Parameter Default Value
RF Path All modules allocated to Layer 1
Max-Input to RIM 37 dBm (RIM level)
ALC ON (RIM level)
UL-Gain Autosymetrical
AGC 0 (system level)
Antenna Internal (system level)
Table 6-4. Default System Values
6.6.3 Navigating the Setup Tool
The following figure shows one of the Setup screens with the main features and options common for all setup screens.
Figure 6-32. Example of Setup Screen (RF-Path Phase)
Navigating the Setup Tool
The process comprises several phases that are displayed in a menu to the left of the screen. The current phase is indicated
by a red circle, where each completed phase shows a green status indicator.
Default values are assigned to all the screen parameters, allowing the user to proceed to the next phase without having to
configure or modify the parameters (if are appropriate for site requirements).
After the Setup procedure has been run at least once, the user can skip phases using the "Next" button until the required
phase is reached.
The user can quit the Setup procedure any time (using the Quit button) and access the tool at any time (using the Setup tab).