User's Manual

Commissioning the System
P/N 709C011801
Page 70
NOTE: If not all of the modules all configured before continuing to the next phase of the setup procedure the following alert
will appear: "Not all devices are configured, are you sure you want to continue?" Click OK to continue to Max Input or Cancel
to configure remaining devices.
Figure 6-24. Unconfigured Devices Alert Message
10. Set the BTS DL Max Expected Power for each RIM.
Select the RIM(s) to be configured. All the RIMs can be selected simultaneously (Select All checkbox), individually or
according to Group (owner), Chassis or Band (service).
Select the BTS DL Max Expected Power.
Note the following:
o Default Max. Expected Power = 30 dBm for unit protection
o Range: -15 dBm to 37 dBm in 1 dB steps
o PCS: 0 to 37 dBm
o A number of RIMs can be configured at a time, however if one of the selected RIMs has a limited range (e.g. PCS)
the Max. Expected Power allowed will be set according to limited range.
Click Submit to apply setting.
Figure 6-25. Setting Max-Input Power
11. Click Next to continue to the ALC (Automatic Level Control) phase:
Select the RIM(s) to be set. All the RIMs can be selected simultaneously (Select All checkbox), individually or according
to Group (owner), Chassis or Band (service).
Enable (ON=default) or disable (OFF) the ALC operation for the selected RIM.