User's Manual
Commissioning the System
P/N 709C011801
Page 70
NOTE: If not all of the modules all configured before continuing to the next phase of the setup procedure the following alert
will appear: "Not all devices are configured, are you sure you want to continue?" Click OK to continue to Max Input or Cancel
to configure remaining devices.
Figure 6-24. Unconfigured Devices Alert Message
10. Set the BTS DL Max Expected Power for each RIM.
• Select the RIM(s) to be configured. All the RIMs can be selected simultaneously (Select All checkbox), individually or
according to Group (owner), Chassis or Band (service).
• Select the BTS DL Max Expected Power.
Note the following:
o Default Max. Expected Power = 30 dBm for unit protection
o Range: -15 dBm to 37 dBm in 1 dB steps
o PCS: 0 to 37 dBm
o A number of RIMs can be configured at a time, however if one of the selected RIMs has a limited range (e.g. PCS)
the Max. Expected Power allowed will be set according to limited range.
• Click Submit to apply setting.
Figure 6-25. Setting Max-Input Power
11. Click Next to continue to the ALC (Automatic Level Control) phase:
• Select the RIM(s) to be set. All the RIMs can be selected simultaneously (Select All checkbox), individually or according
to Group (owner), Chassis or Band (service).
• Enable (ON=default) or disable (OFF) the ALC operation for the selected RIM.