User's Manual

Commissioning the System
P/N 709C011801
Page 55
6 Commissioning the S ystem
After physically installing all of the headend and remote-end elements, the initial setup procedure can be performed and the
system can be commissioned either via a local or remote connection.
NOTE: When unconfigured elements are detected the following message appears in the Config window of the Web Management
GUI: "New uncommissioned units found, please run setup".
The initial setup procedure consists of the following steps:
Opening a local Web Management session (on page 55) using the default IP address assigned to the HEU
Configuring the LAN and LOCAL Port Network Settings (on page 56) for remote or local management
Performing required pre-setup procedures
Running the Setup procedure (on page 62)
Performing the System Adjustment Procedure (on page 73)
6.1 Opening a Local Session
To open a local Web Management session
1. Verify that your computer Local Area Connection (Properties / TCP/IP / Properties) is set to obtain the "DNS Server Address
Automatically".
2. Connect a computer (i.e. laptop) directly to the HEU HCM LOCAL port via the supplied RJ-45 Ethernet cable (P/N
705900003) as shown in the following figure.
WARNING! DO NOT connect the HCM LOCAL port to a network as its DHCP server can disrupt LAN IP addressing.
Figure 6-1. Local Connection Between (HEU) HCM and Computer
3. Assign your computer an IP address to operate in the same subnet as the HCM (default HCM IP address = 193.168.1.1).
4. Open the Web browser and enter the HCM IP Address (default HCM IP address = 193.168.1.1).
Figure 6-2. Entering HCM IP Address into browser