User's Manual

Unit Descriptions - RF Path
P/N 709C011801
Page 35
2.1.2.1 ACM (Auxiliary Control Module)
The ACM provides basic control functions (only) for the host chassis via a local connection. The ACM module can be remotely
managed via an HCM (on page 30) connection.
Figure 2-8. ACM Module
Port Description
INTERNAL
(TO HCM)
[4] RJ45, 100Mb Ethernet ports used for OIU and/or HEU slave management connections
Console [1] RJ45, serial port used for basic IP configuration and local connection for service personnel
Table 2-7. ACM Ports Description
LED Description
PWR
Steady Green - Power supplied to unit
Off No power is supplied to the unit
RUN
Steady Green HCM Boot up sequence complete and functioning
Blinking Green HCM Boot up sequence in process
Off No power supplied to the unit
SYS Indicates overall status of the managed system
FAN
Green Normal operation status
Red Faulty fan (s)
Table 2-8. ACM LED Indicators Description