User's Manual

Introduction
P/N 709C011801
Page 17
1.3.6 Default Network and User Settings
1.3.6.1 Default Network Parameters
The following table identifies the default settings for each of the Network Ethernet ports located on the front panel of the HCM.
Port Name Configuration
LOCAL
DHCP: off
IP: 193.168.1.1
Subnet Mask: 255.255.0.0
LAN
DHCP: Client, or Static IP (default)
IP: 192.168.1.1
Subnet Mask: 255.255.0.0
Internal
DHCP: server on (this local port is set by default set to act as a DHCP Server and provide an
IP address to the connected computer so no configuration of the computer is required)
IP: 11.0.0.1
Subnet Mask: 255.0.0.0
Table 1-10. Default Network Port Parameters
1.3.6.2 System Administrator or "Super User"
One System Administrator or "Super User" is available. This user has the highest access level, does not belong to any group and
is the only user that can create groups.
NOTE: Upon initial login, the System Administrator should create user groups. Each new group created along with a default
Group Administrator.
User Name admin (cannot be modified)
Password default provided by Corning (and should be changed immediately)
Group none (leave blank)
Table 1-11. User Default Info
1.3.6.3 Default Group Admin
Groups can only be created by the Admin user. As a group is created, a default Group Administrator is automatically generated
for that group. The Group Administrator User Name and Password are based on the group name. For example, if the group is
named 'accounting', the default Group Administrator name will be accounting_Admin (note capital ‘A’ in Admin).
The Group Administrator is authorized to create and manage the users for his/her group. See section group passwords for
detailed description of default group_ Admin user.