User's Manual
Introduction
P/N 709C011801
Page 16
1.3.4 Dimensions and Weight of Units
The tables below describe the physical specifications of the ONE™ units.
Table 1-6. RF Path Headend Units
Unit
Dimensions (H x W x D) US
[International]
Weight: lbs [kg]
HEU
7 x 17.3 x 18.95 in [177.8 x 440 x 481.7 mm]
Chassis: 37 lbs [16.8 kg]
Per RIM: 1.9 lbs [0.9 kg]
Per RIX: 1.54 lbs [0.7 kg]
HCM: 2.2 lbs [1.0 kg]
PSM: 1.98 lbs [0.9 kg]
OIU
7 x 17.3 x 18.95 in [177.8 x 440 x 481.7 mm]
Chassis: : 37 lbs [16.8 kg]
Per OIM: 0.7Kg [1.5lbs]
Per OIX: 1.54 lbs [0.7 kg]
ACM: 2.2 lbs [1.0 kg]
PSM: 1.98 lbs [0.9 kg]
Table 1-7. RF Path Remote Units
Unit
Dimensions (H x W x D) US
[International]
Weight: lbs [kg]
ICU 17 x 15 x 19.2 in [430.5 x 379.8 x 488 mm] 5.5 lbs [2.5 kg] – without PSM
RAU (including
mounting bracket)
13.1 x 13.1 x 4 in [332.7 x 332.7 x 101.6 mm]
RAU only = 7.05 lbs [3.2Kg];
RAU+RxU+GEM = 14 lbs [5.5 Kg]
Table 1-8. Digital Path Units
Unit
Dimensions (H x W x D) US
[International]
Weight: lbs [kg]
GEM
1.28 x 3.79 x 5.95 in [32.7 x 96.3 x 151.3 mm]
1.1 lbs [0.5 kg]
GEU-S
5.01 x 10.51 x 3.26 in (including mounting
bracket) [127.5 x 267 x 83 mm]
2.64 lbs [1.2 kg]
1.3.5 Optical Specifications
Parameter Specification
Optical Output Power <9 dBm
Max. Optical Budget 5 dB
Optical Connector
OIM: MTP connector
RAU: LC/APC SM
Fiber Type Corning SMF-28 or Compatible
Wavelength
1310±10nm (Standard)
Maximum Distance (headend to remote end) 2Km (SMF)
Table 1-9. Optical Specifications