1.3.2.2 Safety and Regulatory Approvals
The safety and regulatory specifications listed below are relevant to all ONE™ devices.
Regulation/Standard
Category
Approval
Laser Safety
FDA/CE 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice no.
50 (July 26, 2001) and IEC 60825-1, Amendment 2 (January 2001)
EMC
CE EN 301 489, EN55022, EN 61000
FCC 47 CFR Part 15, 22, 24, 27
Safety
UL 60950
CAN/CSA-C22.2 No.60950-1-03
Fire Safety UL 2043 (Applicable for Antenna Unit Only)
Table 1-2. Safety and Regulatory Approvals
1.3.3 Power Consumption of Units
This section summarizes to power requirements of all ONE™ RF and digital coverage devices.
1.3.3.1 General Power Safety Instructions
• Use only UL approved power supplies.
• Use only the power cables (AC and DC) and any other relevant accessories provided with the unit to connect the power
supply to the ONE™ units.
• All devices connect to 110 to 240VAC power source.
RF Head End Units
Power Consumption for Full
Chassis
HEU
Chassis with 12 RIMs and 2 RIX:
200W
OIU
Chassis with 12 OIMs and 2 OIX:
300W
Table 1-3. RF Headend Units Power Consumption
RF Remote End Units Max. Power Consumption
RAU (alone) 31W
RxU 21.5W
Table 1-4. RF Remote End Units Power Consumption
Digital Remote End Units Power Consumption
GEM installed in RAU 4.5W
GEM installed in Docking station 4.5W
Table 1-5. Digital Path Remote End Power Specifications