User's Manual

SNMP Management P/N 709C011801 Page 142
To Monitor the Managed System
Using the MIB browser, select the desired MIB entry (one of the tables or specific object ID inside the maStd parameters group)
and choose table view (in case of a table) or a simple GET command (in case of a maStd parameter).
NOTE: Set the SNMP manager GET community to the correct community string (default GET community string is "public").
In order to modify a parameter just select the desired object ID, set a desired value and commit (apply the command).
NOTE: Set the SNMP manager SET community to the correct community string (default SET community string is "private").
10.8 List of Traps
Trap Name Description End
OID
controllerFirstRun Controller first run indication 0
controllerPowerUp Controller power up indication 1
controllerAdjustFault HCM Adjustment Fault 2
moduleDisconnected Module disconnected 4
moduleDetected Module detected 5
versionMismatch Module Version Mismatch 6
versionMismatchClear Module Version Mismatch clear 7
configurationMismatch Configuration Mismatch 8
configurationMismatchClear Configuration Mismatch clear 9
hwFailure HW Failure 10
hwFailureClear HW Failure Clear 11
adjustFault Faulty adjustment procedure set 20
adjustFaultClear Adjustment Fault clear 21
installFault Faulty installation 22
installFaultClear Installation Fault clear 23
releaseMismatch Modules have been detected with mismatched versions 24
releaseMismatchClear All Modules Versions OK 25
connectivity Disconnected modules have been detected 26
connectivityClear All Modules are connected 27
acmPSMAOverTemperature ACM Power Supply A over Temperature 100
acmPSMAOverTemperatureClear ACM Power Supply A over Temperature Clear 101
acmOverTemperature ACM Over Temperature 102
acmOverTemperatureClear ACM Over Temperature clear 103
acmPSMBOverTemperature ACM Power Supply B over Temperature 104
acmPSMBOverTemperatureClear ACM Power Supply B over Temperature Clear 105
acmPSMOverTemperature ACM Power Supply Modules Temperature Temp Both 106
acmPSMOverTemperatureClear ACM Power Supply Modules Temperature Clear 107
acmPSMAOutputUnderVoltage ACM Power Supply A Output Under Voltage 108
acmPSMAOutputUnderVoltageClear ACM Power Supply A Output Under Voltage Clear 109