User's Manual

SNMP Management P/N 709C011801 Page 138
10.2 Modifying the Read/Write Community Parameters
Use this option to modify the Read/Write Community Name of the HCM.
To Modify the Read/Write Community Name
1. Click the Management in the menu bar and select SNMP Config in the side bar. The Management pane appears.
2. In the SNMP Configuration area, click Modify.
Figure 10-3. Management-SNMP Config Screen
3. Define the new Read and Write values and click OK.
10.3 SNMP Management using any Third Party SNMP Manager
The MIBs provide information regarding the managed system and general indication of system failure.
NOTE: The Web GUI management application provides a graphical view of the managed network topology, a graphical view of
the managed element parameters and enables identifying the source of the problem at a glance.
The HCM includes several MIB files that enable viewing traps sent by the controller and to configure and monitor the managed
Corning ONEsystem through any third party SNMP manager (such as HP OpenView, CA Unicenter, IBM Tivoli, Castelrock
SNMPc).
Types of MIBs provided:
MIB-II system group parameters group (RFC-1213) A standard MIB supported by all SNMP managed devices.
maEventsthe events in the system and the definitions of the events and their destinations.
maTrapsIncludes the traps in the system and the definitions of the traps and their destinations.