Monitoring and Troubleshooting
P/N 709C011801
Page 132
The following table provides the descriptions for the RAU Device Alarms tab.
Device Alarm
Description
Inconsistent Version Indicates that the module does not have the defined active release
Over Temperature
Indicates that the ambient temperature in the OIM is
≥
75°
◦
C
Antenna
Indicates faulty antenna connectivity –
external antenna not detected;
Severity – major (red)
Service
LTE/CELL/PCS/AWS
Indicates that service has been disabled by user
Configuration Mismatch Unsuccessful adjustment procedure for the selected module
HW Failure
Indicates HW problem during startup or during normal operation;
Severity – minor (yellow)
Optical Pwr Low Red – indicates optical link power (PDI) is < 3dBm
Overall Status
Overall status of enabled (unmasked) alarms. Reflects the maximum
severity of the device alarms.
Table 9-7. RAU Device Alarms Descriptions
9.3.6 RxU View
Click on the RxU under the hosted RAU module in the Network Topology to display the RxU Alarms tab and the module device
view. Note that the RxU device view is in the RAU icon.
Figure 9-13. RxU Alarms Tab and Device View
Figure 9-14. RxU Device View and Overall Status LED
The following table provides the descriptions for the RxU Device Alarms tab.