User's Manual
Monitoring and Troubleshooting
P/N 709C011801
Page 130
Device Alarm
Description
HW Failure
Indicates HW problem during startup or during normal operation; Alarm
severity – minor (yellow)
Overall Status Indicates overall status of enabled (unmasked) alarms
Table 9-5. RIM Device Alarms Descriptions
9.3.4 OIM Device View and Alarms
Click on the OIM hosted by the OIU module in the Network Topology to display the OIM module Alarms tab and the module
device view. When the OIM is selected, the corresponding RIM(s) in the RF path are also indicated (appears green).
Figure 9-9.
OIM Alarms Tab and Device View
Figure 9-10. OIM Device View and Overall Status LED
The following table provides the descriptions for the OIM Alarms tab.
Device Alarm
Description
Inconsistent Version Indicates that the module does not have the defined active release
Optical Power LOW 1/2/3 Red – indicates optical link power (PDI) is < 3dBm
Over Temperature
Indicates that the ambient temperature in the OIM is
≥
75
◦
C
Configuration Mismatch Unsuccessful adjustment procedure for the selected module
HW Failure
Indicates HW problem during startup or during normal operation;
Severity – minor (yellow)
Overall Status
Overall status of enabled (unmasked) alarms. Reflects the maximum
severity of the device alarms.
Table 9-6. OIM Device Alarms Descriptions