User's Manual
Monitoring and Troubleshooting
P/N 709C011801
Page 129
9.3.3 RIM Module Device View and Alarms
Click on the RIM module in the Network Topology to display the RIM device Alarms and the module device view.
NOTE: When the RIM is selected, the RIM module and the associated OIM module appear green in the Device View Mode.
Figure 9-7. RIM Device View and Alarms
Figure 9-8.
RIM Device View Icon
The following table provides the descriptions for the RIM Device Alarms tab.
Device Alarm
Description
Inconsistent Versions Indicates that the module does not have the defined active release
DL Input Power Low
Red (major fault): BTS RF power input to the RIM is at least 15 dB lower
than the configured max. expected power
DL Power Overload
Red (major fault): BTS RF power input to the RIM is at least 3 dB higher
than the value measured during the adjustment procedure.
Service OFF
Indicates that service has been disabled by the user; Severity – minor
(yellow)
DL Power Damage
Indicates that the input RF power level ≥ 43 dB; Severity – minor
(yellow).
In this case the over power protection mechanism is enabled.
Output power
Indicates that the detected power is 20 dBm or more below the configured
output power level
Over Temperature Ambient temperature inside the RIM is > 75
Configuration
Mismatch
Unsuccessful adjustment procedure for the selected module