8.2.3 Group Users Access Levels
A Group user can be assigned one of five Access Levels, where users of different access levels can be defined in the same Group.
The HCM supports up to three simultaneous sessions for multiple users (local/remote access). The login of users is enabled
according to priority when the maximum amount of multiple users are logged in, the HEU terminates the session running for
the lowest level user logged in the longest (user receives alert message and force logout is performed) in order to enable a
higher access level user to login to the system. A message indicating logon denial appears when the maximum number of users
are logged in and a lower level user attempts to log in to the system.
Figure 8-8. Access Levels
NOTE: Any number of users with the same user levels (including Group Administrators) can be created per group, for a
maximum of 20 users per group (up to 500 per system).
Level Description
Operator R/O access to Monitor, Config and Events screens.
Installer R/O Access to Monitor, Config and Events screens.
Write access to
free text parameters
to allow defining location and
identification information.
RF Tech Access to Commissioning Wizard and Monitor, Config and Events screens:
Write access to all
RF
parameters
R/O to all other parameters
IT Tech Access to Monitor, Config and Management screens:
Write access to all
non-RF
parameters
Access to activity log of all users and groups
HEU SW upgrade
R/O to all other parameters
(Group) Administrator Capabilities:
All IT Tech capabilities
Can create and manage users in this group.
Table 8-2.Group Access Level descriptions