User's Manual

Table Of Contents
Installation RF Path Elements CMA-331-AEN Page 79
Draft
For PSM-DC
General information:
The PSM-DC is provided with six terminal rings (PN: 708A043001)
Type of terminal ring provided: PMNF2-3R-C or PMV2-3RB-3K (depending on availability)
PSM-DC power source rating: 48 V DC; 9A max.
To power up the PSM-DC module:
3. Crimp the provided terminal rings onto the DC wire pairs.
IMPORTANT! Make sure to use an appropriate crimper do not use a plier!
Figure 5-17. Crimping the Terminal Rings onto the DC Wire
Required information:
Type of terminal ring crimped onto DC wires PANDUIT ring terminal:
Compatible wire size: 1.5 2.5mm² wire range/14AWG to 16AWG
M3 stud size
No. of required wire pairs:
Remote feed - three pairs; 100 W max. per pair
Local Plant feed - two pairs; 100 W max. per pair
4. Connect crimped terminal rings to DC connectors.
IMPORTANT! Verify that the DC power source is OFF before connecting the wire pairs!
Figure 5-18. Connecting PSM-DC Wire Pairs
Max. current consumption per pair:
Remote feed = 1.55 A
Plant feed = 4.65 A
For optimal cable management, route all wire pairs to the left side of the rack