5.1.1.6 RIX to OIX Connections
Note: Each RIX module supports connections to up to two OIX modules (in OIU/IHU).
Using the appropriate length ERFC cable (according to distance of available OIX port) connect the HEU RIX module 9-Pin
connector to the corresponding connector on the OIX module. See Figure 5-9.
Refer to Section 5.1.1.7 for schematic diagram of coax connections in a maximum HEU-OIU configuration of 4x4 where all HEU
units are connected to all OIU units.
Figure 5-9. HEU to OIU Coax Connections