User's Manual

Table Of Contents
CMA-331-AEN Page 174
Draft
PSM-AC
(See PSM-AC in HEU section for description and interfaces)
IHU Max Power Consumption (Full Chassis): 300 W
PSM-DC
(See PSM-DC in HEU section for description and interfaces)
IHU Max Power Consumption (Full Chassis): 300 W
Physical
Characteristics
(Chassis and
Modules)
Mounting: Rack-mount 19 in , 4U
Dimensions (H x W X D):
Chassis: 7 x 17.3 x 15.5 in
(177.8 x 440 x 394 mm)
Weight:
Chassis:
30 lbs (14 kg)
Per RIM: 1.9 lbs (0.9 kg)
Per OIM:
1.5 lbs (0.7kg)
RIX: 1.54 lbs (0.7 kg
OIX:
1.54 lbs (0.7 kg)
ACM: 2.2 lbs (1.0 kg)
PSM:
1.98 lbs (0.9 kg)
Interconnect Unit (ICU)
ICU will host the following modules:
15. PSM-I; Power Supply Module, up to four PSM-I modules can be installed.
16. Pretium EDGE
®
Module MTP
®
to LC APC splice module/cassette/field-term cassette. Up to two EDGE
®
Modules
can be installed.
Chassis Interfaces
Power Input: 110-240 V AC, 50-60 Hz power
Output: Eight DC ports- 57 V DC, Max. 60V (UL limit)
Pretium Edge
®
Module
Interfaces
Pretium EDGE® Module, 12 F, LC APC to MTP®
APC Connector, Single-mode (OS2)
Pretium Edge
®
Splice
Cassette Interfaces
12 F, LC duplex, Single-mode APC, single-fiber
Pretium Edge
®
Field-Term
Cassette Interfaces
12 F, LC duplex, Single-mode APC, No Pigtail
Power Consumption
ICU with four PSM-I: 942 W
Physical Characteristics
(Chassis)
Mounting: Rack-mount 19 in 1U
Dimensions
(H x W x D):
1.74 x 17 x 19.2 in
(44.4 x 431.8 x 11.96 mm)
Weight: 5.5 lbs (2.5 kg) – without PSM