CMA-331-AEN Page 157
Draft
Figure 7-2. RxU Module Assembly
3. If required by site planner - connect the filter to the RF filter connectors on the RxU. Refer to Figure 8-3 for location of RxU
filter connections.
Note: Refer to section 5.2.3 for Cavity Filter installation and connections.
Figure 7-3. Assembled RxU Interfaces
4. Verify that RAU LEDs on, on front cover (see Figure 8-4) indicate normal operation status:
LED
Description
LINK Steady Green - Optical link power to/from the RAU is normal
Blinking Green - Optical power from remote is lower than required
Off No optical link detected
POWER Steady Green - Input power within required range detected
Off No power supplied to RAU
RUN Blinking Green RAU boot up sequence complete and module SW up and running
Off No power supplied to unit