User's Manual

Table Of Contents
Installation RF Path Elements CMA-331-AEN Page 137
Draft
5.2.3.6 Main Power Connections
RAU5 MAIN POWER (for RAU5/RAU5+RxU) DC input power connections (see Figure 5-93) connect DC wire pair to the
terminal block connector:
Power input range: 37 to 57 VDC
Wire size: 12-30 AWG
Max. consumption:
RAU5: 44.5 V; 48 W
RAU5 + RxU: 44.5 V; 73 W
Figure 5-93 RAU5 Main Power DC Connections
5.2.3.7 GEM Connections (for Configurations including GEM Modules)
1. Connect DC wire pair to the RAU5 Secondary Power DC input connector (see Figure 5-94):
Wire size: 12-30 AWG
Max. Consumption:
RAU5 + GEM: 44.5 V ; 52W
RAU5 + RxU + GEM: 44.5 V ; 77W
For 2 PoE ports of 802.3af: 43V ; 30 W (Input range: 43 57 V DC)
For 2 PoE ports of 802.3af: 52V ; 62 W (Input range: 52 57 V DC)
Figure 5-94. RAU5 MAIN and SECONDARY DC Input Connections